Envelope interchange · 3.94×24.76 in

100×629 mm filter elements

51 elements from 1 brand(s) share this envelope: 100 mm outside diameter and 629 mm overall length (3.94×24.76 in).

Dimensional interchange — verify before substituting. These cartridges fit the same bowl space; they are not guaranteed drop-in equivalents. Compare grade, end caps, seals, collapse rating and bypass configuration for the specific duty.
ModelBrandID (mm)Micronβ ratingCollapse (bar)BypassSealType
NL-1000-B-10-B STAUFF 60.3 — — — housing — inline
NL-1000-B-10-V STAUFF 60.3 — — — housing — inline
NL-1000-B-100-B STAUFF 60.3 — — — housing — inline
NL-1000-B-100-V STAUFF 60.3 — — — housing — inline
NL-1000-B-125-B STAUFF 60.3 — — — housing — inline
NL-1000-B-125-V STAUFF 60.3 — — — housing — inline
NL-1000-B-25-B STAUFF 60.3 — — — housing — inline
NL-1000-B-25-V STAUFF 60.3 — — — housing — inline
NL-1000-B-250-B STAUFF 60.3 — — — housing — inline
NL-1000-B-40-B STAUFF 60.3 — — — housing — inline
NL-1000-B-40-V STAUFF 60.3 — — — housing — inline
NL-1000-B-60-B STAUFF 60.3 — — — housing — inline
NL-1000-B-60-V STAUFF 60.3 — — — housing — inline
NL-1000-B-80-B STAUFF 60.3 — — — housing — inline
NL-1000-E-03-B STAUFF 60.3 — — — housing — inline
NL-1000-E-03-V STAUFF 60.3 — — — housing — inline
NL-1000-E-06-B STAUFF 60.3 — — — housing — inline
NL-1000-E-06-V STAUFF 60.3 — — — housing — inline
NL-1000-E-10-B STAUFF 60.3 — — — housing — inline
NL-1000-E-10-V STAUFF 60.3 — — — housing — inline
NL-1000-E-16-B STAUFF 60.3 — — — housing — inline
NL-1000-E-16-V STAUFF 60.3 — — — housing — inline
NL-1000-E-25-B STAUFF 60.3 — — — housing — inline
NL-1000-E-25-V STAUFF 60.3 — — — housing — inline
NL-1000-F-03-B STAUFF 60.3 — — — housing — inline
NL-1000-F-03-V STAUFF 60.3 — — — housing — inline
NL-1000-F-05-B STAUFF 60.3 — — — housing — inline
NL-1000-F-06-B STAUFF 60.3 — — — housing — inline
NL-1000-F-06-V STAUFF 60.3 — — — housing — inline
NL-1000-F-10-B STAUFF 60.3 — — — housing — inline
NL-1000-F-16-B STAUFF 60.3 — — — housing — inline
NL-1000-F-16-V STAUFF 60.3 — — — housing — inline
NL-1000-F-25-B STAUFF 60.3 — — — housing — inline
NL-1000-F-25-V STAUFF 60.3 — — — housing — inline
NL-1000-F10-V STAUFF 60.3 — — — housing — inline
NL-1000-K-10-B STAUFF 60.3 — — — housing — inline
NL-1000-K-10-V STAUFF 60.3 — — — housing — inline
NL-1000-K-25-B STAUFF 60.3 — — — housing — inline
NL-1000-K-25-V STAUFF 60.3 — — — housing — inline
NL-1000-W-10-B STAUFF 60.3 — — — housing — inline
NL-1000-W-10-V STAUFF 60.3 — — — housing — inline
NL-1000-W-100-B STAUFF 60.3 — — — housing — inline
NL-1000-W-100-V STAUFF 60.3 — — — housing — inline
NL-1000-W-200-B STAUFF 60.3 — — — housing — inline
NL-1000-W-200-V STAUFF 60.3 — — — housing — inline
NL-1000-W-25-B STAUFF 60.3 — — — housing — inline
NL-1000-W-25-V STAUFF 60.3 — — — housing — inline
NL-1000-W-40-B STAUFF 60.3 — — — housing — inline
NL-1000-W-40-V STAUFF 60.3 — — — housing — inline
NL-1000-W-60-B STAUFF 60.3 — — — housing — inline
NL-1000-W-60-V STAUFF 60.3 — — — housing — inline

Substitution verification checklist

  1. Filtration grade. Compare at the same ISO 16889 Beta test point — “10 µm nominal” and “12 µm β1000” may be the same physical media.
  2. End caps & O-rings. Open/closed cap style and seal position block interchange even with identical OD/length.
  3. Seal compound. NBR is standard for mineral oil; phosphate-esters, high temperatures or bio-oils can demand fluorocarbon.
  4. Collapse rating. Low-collapse (~20 bar) return elements must never replace high-collapse (210 bar) pressure elements.
  5. Bypass strategy. Integral bypass valves (e.g. 3.4 bar) vs reusable housing valves change cold-start behaviour.

Frequently asked questions

Are all 100×629 mm filter elements interchangeable?
They share the same physical envelope — 100 mm OD and 629 mm length (3.94×24.76 in) — so they fit the same bowl. Interchangeability ends there: micron/Beta rating, end-cap geometry, seals, collapse rating and bypass configuration differ across the 51 elements listed and must be checked against the duty.
Is it a drop-in replacement if the OD and length match?
Only after verification. Confirm in order: (1) the filtration grade meets the ISO 4406 cleanliness target at the same Beta test point, (2) end-cap and O-ring arrangement is identical, (3) seal compound suits the fluid (NBR vs fluorocarbon), (4) collapse/burst rating fits pressure-line or cold-start conditions, and (5) the bypass strategy (integral valve vs housing valve) matches.
What is 100×629 mm in inches?
100×629 mm converts to approximately 3.94×24.76 in.

Browse all 100 mm OD elements or open the dimensions finder.

Request quote & availability

First reply within 2 business hours · first quotation — including the original brand and 1–2 verified equivalents — within 24 hours on business days.