HYDAC · Betamicron 4 R · return line
0240 R 010 BN4HC filter element: specifications & equivalents
The 0240 R 010 BN4HC is a HYDAC return-line hydraulic filter element, built with betamicron 4 microglass (bn4hc) media, sized 74 × 204 mm OD × length (ID 34 mm), rated at 10 µm class (β12(c) ≥ 1000 per ISO 16889 (10 µm at β ≥ 200)). Verify against the current manufacturer data sheet before ordering.
Dimensions and weight are compiled from two independent aftermarket listings; confirm against the HYDAC housing drawing before ordering.
Specification table
| Parameter | Value |
|---|---|
| Filter type | return line |
| Media | Betamicron 4 microglass (BN4HC) |
| Filtration rating | 10 µm |
| Rating basis | nominal |
| Beta ratio | β12(c) ≥ 1000 per ISO 16889 (10 µm at β ≥ 200) |
| Outside diameter OD | 74 mm |
| Inside diameter ID | 34 mm |
| Length | 204 mm |
| Nominal length code | 6 in |
| Flow direction | outside-in |
| Collapse / burst pressure | 20 bar |
| Integral bypass valve | none (housing/valve-dependent) |
| Seal material | Nitrile (NBR) |
| Operating temperature | -30 to 100 °C |
| Mass | 600 g |
| Source catalog | Pall Corporation: Red1000 Series Filter Element Interchange List (M&EREDCOMPEN (Pall literature library)) HYDAC / Airline Hydraulics: Betamicron Filter Elements BAMA Filtration (filtersfilter.com): Replacement HYDAC hydraulic return filter 0240R010BN4HC Heboke / Gu’an Fangte Filter (made-in-china.com): 0240R010BN4HC replacement element |
| Last verified | 2026-09-27 |
Sources: Pall Corporation — Red1000 Series Filter Element Interchange List · HYDAC / Airline Hydraulics — Betamicron Filter Elements · BAMA Filtration (filtersfilter.com) — Replacement HYDAC hydraulic return filter 0240R010BN4HC · Heboke / Gu’an Fangte Filter (made-in-china.com) — 0240R010BN4HC replacement element — accessed 2026-09-26.
HYDAC® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized HYDAC distributor.
Dimensions & series range
| Outside diameter | 74 mm (2.913 in) |
| Inside diameter | 34 mm (1.339 in) |
| Overall length | 204 mm (8.031 in) |
| Nominal length code | 6 inches |
All 74×204 mm interchange elements →
Cross references & equivalents
| Equivalent model | Brand | Match level | Note |
|---|---|---|---|
| ↔ HC2218FCS6H | Pall | full | Direct fit per Pall’s Red1000 interchange list (no adaptor). Grades print differently — HYDAC 010 code vs Pall 12 µm β>1000 — the two conventions describe the same multipass-tested grade; verify cleanliness targets for critical drives. For housings using the reusable bypass valve. |
| ↔ HC2226FCS6H50 | Pall | partial | Same envelope and 12 µm β>1000 grade, but this Red1000 execution has an integral 3.4 bar (50 psid) bypass valve; the plain execution leaves bypass control to the housing valve. Match the existing valve strategy before substituting. |
|
↔ 14470812 page in verification queue | UFI | verify | UFI hydraulic element number quoted in the aftermarket table; confirmation pending. |
|
↔ 938279Q page in verification queue | Aftermarket | verify | Parker return-line cartridge quoted in aftermarket interchange lists; verify end-cap and bypass configuration. |
|
↔ DC240CA10ANP page in verification queue | MP Filtri | verify | MP Filtri DC-series element for 0240-size return housings; verify seal and valve options. |
|
↔ HC2226FKS6H page in verification queue conflict | Pall | verify | Quoted by aftermarket source (s4) but Pall’s official list prints HC2226FCS6H50 for this position — grade/configuration conflict; confirm before ordering. |
|
↔ HD829 page in verification queue | MANN-FILTER | verify | MANN-FILTER industrial element quoted against 0240R010BN4HC; verify micron rating convention. |
|
↔ HF6889 page in verification queue | Fleetguard | verify | Fleetguard HF-series hydraulic cartridge quoted for the 0240 R envelope; verify before fleet substitution. |
|
↔ P170617 page in verification queue | Donaldson | verify | Aftermarket table quotes this Donaldson cartridge; envelope and micron not yet catalog-verified. |
|
↔ P566979 page in verification queue | Donaldson | verify | Second Donaldson number in the same aftermarket row; confirm which execution matches the RF housing. |
|
↔ PR3292 page in verification queue | Parker | verify | Parker PR-series number quoted alongside 938279Q; catalog confirmation pending. |
|
↔ R84E10GV page in verification queue | WIX | verify | WIX industrial return-filter cartridge; aftermarket-quoted only. |
| ↔ RE-070-G-10-B | STAUFF | verify | STAUFF RE-series replacement element per aftermarket table; check grade-code equivalence (10 µm class). |
Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.
How the 0240 R 010 BN4HC model number is decoded
- 0240Element size code for the HYDAC RF/RFM return-filter housing family (0240 size).
- RReturn-line element (installed in a tank-top return filter).
- 010Filtration grade code: 10 µm class (12 µm(c) at β ≥ 1000 per the ISO 16889 multipass convention used in Pall’s interchange list).
- BN4HCBetamicron 4 microglass media, low-collapse execution (~20 bar collapse pressure) with nitrile seals; BH4HC is the 210 bar high-collapse variant.
Typical equipment & applications
- Tank-mounted return-line hydraulic filters
- Hydraulic power units and lubrication systems
- Construction and agricultural machinery
- Machine tool and industrial hydraulic systems
Selection pitfalls — read before you substitute
- A return-line element is not a pressure-line element: return cartridges (BN4HC low-collapse) tolerate roughly 20 bar differential, while BH4HC pressure executions are rated to 210 bar. Installing a low-collapse element in a pressure housing can rupture the media on cold-start spikes.
- This element has no integral bypass — opening pressure is set by the housing’s reusable bypass valve. Confirm the valve setting (commonly 3.4 bar) is present before fitting.
- “10 µm nominal” and “12 µm at β1000” can describe the very same media — one is reported at β≥200, the other at β≥1000 per ISO 16889. Compare ratings at the same Beta test point, not just the printed micron number.
- Nitrile (NBR) seals are standard for mineral hydraulic oil but fail early in some phosphate-ester fluids and at sustained high temperature; verify seal compound against the fluid data sheet (fluorocarbon/Viton executions may be required).
- End-cap geometry and the number/position of O-rings block interchange even when OD and length match — visually compare end caps before fitting, especially with aftermarket cartridges.
Frequently asked questions
What are the dimensions of the 0240 R 010 BN4HC filter element?
What micron rating does 0240 R 010 BN4HC use?
What replaces the 0240 R 010 BN4HC filter element?
How do I read the 0240 R 010 BN4HC part number?
Is a same-envelope aftermarket element always a drop-in replacement?
How often should a hydraulic return-line element be replaced?
Same-envelope elements from other brands
View full interchange →These 3 catalog element(s) share the 74×204 mm envelope. Envelope match alone does not guarantee interchangeability — compare micron/Beta, seals and collapse rating.
Other models in the Betamicron 4 R series
All 52 →Reviewed & verified by the ElementRef engineering desk against Pall Corporation and HYDAC / Airline Hydraulics and BAMA Filtration (filtersfilter.com) and Heboke / Gu’an Fangte Filter (made-in-china.com) on 2026-09-27. Read our editorial & correction policy.