STAUFF · Replacement Elements · inline line
SP-070-E-03-B filter element: specifications & equivalents
The SP-070-E-03-B is a STAUFF inline-line hydraulic filter element, sized 80 × 208.5 mm OD × length (ID 43.5 mm). Verify against the current manufacturer data sheet before ordering.
Micron rating, media type, collapse pressure and seal material are not printed in the STAUFF interchange listing and are pending extraction from STAUFF product data sheets. Verify against the current STAUFF catalog before ordering.
Specification table
| Parameter | Value |
|---|---|
| Filter type | inline line |
| Outside diameter OD | 80 mm |
| Inside diameter ID | 43.5 mm |
| Length | 208.5 mm |
| End caps | open-ended cartridge element |
| Integral bypass valve | none (housing/valve-dependent) |
| Source catalog | STAUFF: STAUFF Filter Interchange online database (filterinterchange.com) |
| Last verified | 2026-09-27 |
Sources: STAUFF — STAUFF Filter Interchange online database (filterinterchange.com) — accessed 2026-09-27.
STAUFF® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized STAUFF distributor.
Dimensions & series range
| Outside diameter | 80 mm (3.150 in) |
| Inside diameter | 43.5 mm (1.713 in) |
| Overall length | 208.5 mm (8.209 in) |
All 80×209 mm interchange elements →
Cross references & equivalents
| Equivalent model | Brand | Match level | Note |
|---|---|---|---|
|
↔ 00313039 page in verification queue | UFI | partial | STAUFF Filter Interchange lists 00313039 (HYDAC) as replaced by SP-070-E-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 1269912 page in verification queue | UFI | partial | STAUFF Filter Interchange lists 1269912 (HYDAC) as replaced by SP-070-E-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
| ↔ 57849 | WIX Filters | partial | STAUFF Filter Interchange lists 57849 (WIX) as replaced by SP-070-E-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 77783459 page in verification queue | UFI | partial | STAUFF Filter Interchange lists 77783459 (COMEX / Ecoparts) as replaced by SP-070-E-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 7783459 page in verification queue | UFI | partial | STAUFF Filter Interchange lists 778.345.9 (MAHLE / Filtration Group) as replaced by SP-070-E-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 9313259 page in verification queue | UFI | partial | STAUFF Filter Interchange lists 9313259 (MAHLE / Filtration Group) as replaced by SP-070-E-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 932285Q page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 932285Q (PARKER) as replaced by SP-070-E-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ C7272 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists C7272 (FRAM) as replaced by SP-070-E-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ H960008003BN page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists H9600/08 003 BN (HYDAC) as replaced by SP-070-E-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ HPQ98298 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists HPQ98298 (HY-PRO) as replaced by SP-070-E-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ P9600D08N2003 page in verification queue | Donaldson | partial | STAUFF Filter Interchange lists P9600D08N2003 (COMEX / Ecoparts) as replaced by SP-070-E-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ P9600D08N3 page in verification queue | Donaldson | partial | STAUFF Filter Interchange lists P9600D08N3 (COMEX / Ecoparts) as replaced by SP-070-E-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ R928016945 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists R 928016945 (EPE / Bosch-Rexroth Filtration) as replaced by SP-070-E-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ STU226 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists STU-226 (NORMAN) as replaced by SP-070-E-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ WGPP9608 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists WGPP 9608 (WOODGATE) as replaced by SP-070-E-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.
How the SP-070-E-03-B model number is decoded
- SP-070-E-03-BSTAUFF replacement element part number per the STAUFF Filter Interchange database.
Typical equipment & applications
- Replacement element for OEM hydraulic filter housings
Selection pitfalls — read before you substitute
- “10 µm nominal” and “12 µm at β1000” can describe the very same media — one is reported at β≥200, the other at β≥1000 per ISO 16889. Compare ratings at the same Beta test point, not just the printed micron number.
- Nitrile (NBR) seals are standard for mineral hydraulic oil but fail early in some phosphate-ester fluids and at sustained high temperature; verify seal compound against the fluid data sheet (fluorocarbon/Viton executions may be required).
- End-cap geometry and the number/position of O-rings block interchange even when OD and length match — visually compare end caps before fitting, especially with aftermarket cartridges.
Frequently asked questions
What are the dimensions of the SP-070-E-03-B filter element?
What replaces the SP-070-E-03-B filter element?
How do I read the SP-070-E-03-B part number?
Is a same-envelope aftermarket element always a drop-in replacement?
How often should a hydraulic return-line element be replaced?
Same-envelope elements from other brands
View full interchange →These 12 catalog element(s) share the 80×209 mm envelope. Envelope match alone does not guarantee interchangeability — compare micron/Beta, seals and collapse rating.
Other models in the Replacement Elements series
All 3832 →Reviewed & verified by the ElementRef engineering desk against STAUFF on 2026-09-27. Read our editorial & correction policy.