WIX Filters · 57xxx · return line

57682 filter element: specifications & equivalents

The 57682 is a WIX Filters return-line hydraulic filter element, built with wire/glass media, sized 94.6 × 137.4 mm OD × length. Verify against the current manufacturer data sheet before ordering.

Envelope OD × L 94.6 × 137.4 mm
Media Wire/Glass
Line type return
Catalog verified. Parameters extracted from the manufacturer’s electronic catalog / official interchange document and checked 2026-09-27. Confidence score 0.90.

Specification table

ParameterValue
Filter type return line
Media Wire/Glass
Rating basis nominal
Outside diameter OD 94.6 mm
Length 137.4 mm
End caps open-ended cartridge element (no baseplate)
Flow direction outside-in
Integral bypass valve none (housing/valve-dependent)
Seal material Nitrile (NBR)
Manufacturer part no. 57682
Source catalog WIX Filters (MANN+HUMMEL): WIX Filters online product catalog
Last verified2026-09-27

Sources: WIX Filters (MANN+HUMMEL) — WIX Filters online product catalog — accessed 2026-09-26.

WIX Filters® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized WIX Filters distributor.

Dimensions & series range

Outside diameter94.6 mm (3.724 in)
Overall length137.4 mm (5.409 in)

Cross references & equivalents

No catalog-verified cross references yet. This model is in the manual verification queue — request a verified equivalent.

Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.

How the 57682 model number is decoded

  • 57682WIX hydraulic cartridge element part number.
  • 94.6 mm OD / undefined mm IDCartridge envelope (outside/inside diameter); no mounting thread.
  • Wire/GlassFilter media: Wire/Glass.

Typical equipment & applications

  • Mobile and industrial hydraulic return circuits
  • Construction and agricultural equipment
  • Heavy-duty transmission and torque-converter circuits

Selection pitfalls — read before you substitute

  • A return-line element is not a pressure-line element: return cartridges (low-collapse) tolerate roughly 20 bar differential, while BH4HC pressure executions are rated to 210 bar. Installing a low-collapse element in a pressure housing can rupture the media on cold-start spikes.
  • This element has no integral bypass — opening pressure is set by the housing’s reusable bypass valve. Confirm the valve setting (commonly 3.4 bar) is present before fitting.
  • “10 µm nominal” and “12 µm at β1000” can describe the very same media — one is reported at β≥200, the other at β≥1000 per ISO 16889. Compare ratings at the same Beta test point, not just the printed micron number.
  • Nitrile (NBR) seals are standard for mineral hydraulic oil but fail early in some phosphate-ester fluids and at sustained high temperature; verify seal compound against the fluid data sheet (fluorocarbon/Viton executions may be required).
  • End-cap geometry and the number/position of O-rings block interchange even when OD and length match — visually compare end caps before fitting, especially with aftermarket cartridges.

Frequently asked questions

What are the dimensions of the 57682 filter element?
The published envelope is 94.6 mm OD × 137.4 mm length (3.724 × 5.409 in). Confirm against the housing drawing before ordering.
What replaces the 57682 filter element?
Cross references are being verified for this model — use the inquiry form and the engineering desk will confirm equivalents.
How do I read the 57682 part number?
See the designation decoder above: each segment of 57682 encodes size, line type, filtration grade and media/collapse execution.
Is a same-envelope aftermarket element always a drop-in replacement?
No. Matching OD and length only proves the cartridge fits the bowl. End-cap style, seal compound, micron/Beta rating, collapse pressure and bypass configuration must also match; the table above tags every equivalent as full, partial or verify for exactly this reason.
How often should a hydraulic return-line element be replaced?
Replace at the housing manufacturer’s recommended differential-pressure setting (commonly signalled by a clogging indicator), or on a time-based service interval when no indicator is fitted — never wait for bypass to open continuously, because unfiltered oil then reaches the valves.

Other models in the 57xxx series

All 221 →

Reviewed & verified by the ElementRef engineering desk against WIX Filters (MANN+HUMMEL) on 2026-09-27. Read our editorial & correction policy.